Electrochemistry: potentiostat, galvanostat, EIS, FC test station

 

*


Help/download


Important Notes

  • The links marked with a requires a login and password which will be emailed (by a human) to you once you register your instrument.
  • You can use the following link to register your instrument or ask for help.
  • Please use the following link to fill our online survey. It is very important for us to know where we need to improve.
  • The username & password have changed October 1st 2007, you may need to register again.

 

EC-Lab® Express V5.12

 

EC-Lab® V9.46

Notes:

  • For full versions, If the version previously installed was V8.00 or higher, you will be prompted for a fast and automatic firmware upgrade when establishing the first connection to the instrument. This firmware upgrade will be using the Ethernet connection only and thus you will not need the serial connection. If the version previously installed was V7.01 or lower, you will need to install a new firmware (included in EC-Lab full version with manuals & Tera Term Pro download) using a serial communication. See the latest VMP or VMP2 or MPG user's manual for firmware installation.
  • The setup program installs the PDF files into the "./Manual" folder ("." being the directory where the EC-Lab has been installed). Then the manual can be opened directly or with EC-Lab through the menu : "?, Manual".
  • EC-Lab® detailed history
  • What would you like to see next in EC-Lab? Please send us your requests. We continuously improve our software and we value very much your feedback.

EC-Lab® development package

  • EC-Lab® development package V5.02 - please contact us

 

FC-Lab® V5.11

 

 

Application notes:
(List updated on April 4, 2008)

  • AN#1 - Protocols for studying intercalation electrodes materials: Part I: Galvanostatic cycling with potential limitation (GCPL)
  • AN#2 - Protocols for studying intercalation electrodes materials: Part II: Potentiodynamic Cycling with Galvanostatic Acceleration (PCGA)
  • AN#3 - Galvanostatic Cycling with Potential limitation 4: Low Earth Orbit battery satellite protocol
  • AN#4 - Potentiostat stability mystery explained
  • AN#5 - Precautions for good impedance measurements
  • AN#6 - Constant Power protocol Application
  • AN#7 - Application of the bipotentiostat to an experiment with a rotating ring-disk electrode.
  • AN#8 - Impedance, admittance, Nyquist, Bode, Black, etc.
  • AN#9 - Linear vs. non-linear systems in impedance measurements
  • AN#10 - Corrosion current measurement for an iron electrode in an acid solution
  • AN#11 - Calculation of the platinum’s active surface
  • AN#12 - UV-Visible Spectroscopy and Electrochemistry coupling: Spectro-electrochemical experiment faisability on a polypyrrol film
  • AN#13 - VMP3 and Quartz Crystal Microbalance coupling: mass measurement during a polypyrrol film deposition
  • AN#14 - ZFit and equivalent electrical circuits
  • AN#15 - Two questions about Kramers-Kronig transformations
  • AN#16 - Simultaneous Impedance measurements on each element of a running cell stack
  • AN#17 - Drift correction in electrochemical impedance measurements

Technical notes:
(accessible to registered users only - List updated on May 12, 2008)

  • TN#0 - Problem upgrading the VMP/VMP2 firmware under Win2000 or WinXP
  • TN#1 - VMP2 or BiStat IP address change
  • TN#1bis - VMP or MPG IP address change
  • TN#2 - Accessing the VMP2 (or BiStat) from other networks through gateways
  • TN#2bis - Accessing the VMP (or MPG) from other networks through gateways
  • TN#3 - Computer TCP/IP installation and configuration
  • TN#4 - VMP2, VMP or MPG firmware upgrading
  • TN#5 - Importing a VMP text file into Excel on line
  • TN#6 - The Data smooth option
  • TN#7 - The "compact" Function in the PCGA protocol
  • TN#8 - Adjustment of the potential control resolution
  • TN#9 - Other channel to cell connection mode - Part I: Ewe vs Ece control in the standard mode
  • TN#10 - "p" low current option: installation and calibration
  • TN#11 - Other channel to cell connection mode - Part II: CE to Ground mode
  • TN#12 - VMP2 low current N'Stat box installation
  • TN#13 - VMP2/Z and Bistat long cell cables
  • TN#14 - The Smooth scan option in the cyclic voltammetry protocol
  • TN#15 - Low current option: measurement precautions
  • TN#16 - Influence of the temperature for impedance measurements on circuit #2 of Test Box-3
  • TN#17 - Instantaneous versus averaged current measurement
  • TN#18 - Channel board: installation and calibration
  • TN#19 - Network parameters configuration with the ARM communication board
  • TN#20 - MEASURE versus CONTROL mode: extended current ranges
  • TN#21 - External device control and recording

Handbook of Electrochemical Impedance Spectroscopy:
(by courtesy of Jean-Paul Diard, Bernard Le Gorrec, Claude Montella)

Interactive Faradaic impedance library - require Free Mathematica Player
(by courtesy of Jean-Paul Diard, Bernard Le Gorrec, Claude Montella)

Etude de réactions électrochimiques par SIE:
(by courtesy of Jean-Paul Diard, Bernard Le Gorrec, Claude Montella)

MacPile Support section

Please click here

 

TOP


< Copyright and sales information >