| Cell Vials
Various shapes and sizes of PYREX glass cell vials are available
for users' purposes. Please be referred to their capacity as well.
 

|
Catalog No. |
Description |
Sample Volume |
Quantity |
Application |
|
A-001056 |
Sample vial |
20 mL |
10 pcs |
VC-2, VC-3, VC-5, SVC-3, MCA |
|
A-011504 |
Sample vial |
5 mL |
10 pcs |
VC-4 |
|
A-001051 |
Water Jacketed Glass cell |
20 mL |
1 pc |
VC-2, VC-3, VC-5, SVC-3, MCA |


|
Catalog No. |
Description |
Sample Volume |
Quantity |
Application |
|
A-012062 |
Sample vial for RRDE-3 |
60 mL |
12 pc |
RRDE-3 |
|
A-012018 |
Water Jacketed Cell vial |
60 mL |
1 pc |
RRDE-3 |

|
Catalog No. |
Description |
Sample Volume |
Quantity |
Application |
|
A-012061 |
Glassware |
20 mL |
12 pc |
RDE-2, RRDE-3 |
|
A-009987 |
Water Jacketed Cell vial |
20 mL |
1 pc |
RDE-2 |
Accessories
|
Catalog No. |
Description |
|
A-011226 |
Cell holder for 5 mL vial |
|
A-001209 |
Cell holder for 20 mL vial |
VC-2 Voltammetry cell
Counter electrode of Voltammetry cell for VC-2 is exchangeable.
Teflon-coated cell cap equips removable teflon-coated working
electrode holder. Sample holder for the measurement with a small
volume (100 - 200 µL) is available as an optional component.


Components of VC-2/VC-3 cell can be provided separately. In that
case, each sample vial (010343) includes 10 pieces per the sales
unit.
|
Catalog No. |
Description |
|
A-001052 |
VC-2 Voltammetry cell |
|
Contents |
|
A-001056 |
Sample
vial (20 ml) 7 pcs |
|
A-002222 |
Pt
counter electrode for VC-2 cell |
|
A-009028 |
Teflon
cap for VC-2 |
|
A-010537 |
Purging
tube |
VC-3 Voltammetry cell
Voltammetry cells consist of 4 kinds of products - platinum
counter electrode, sample vials, teflon cap and gas purging tube.


|
Catalog No. |
Description |
|
A-002232 |
VC-3 Voltammetry
cell |
|
Contents |
|
A-001056 |
Sample vial (20 ml) 7
pcs |
|
A-002233 |
5 cm Platinum counter
electrode for VC-3 cell |
|
A-009035 |
Teflon cap for VC-3 |
|
A-010537 |
Purging tube |
VC-4 Voltammetry cell


Capable for measuring of 1 - 3 ml of sample volume using electrodes
with 6 mm of the diameter. Furnished holder prevents the vial from
spilling.
|
Catalog No. |
Description |
 |
|
A-011224 |
VC-4 Voltammetry cell |
|
Contents |
|
A-011504 |
Sample
vial (5 ml) 7 pcs |
|
A-011226 |
Teflon
cap for VC-4 |
|
A-011227 |
Cell
holder for VC-4 |
|
A-002222 |
Pt
counter electrode for VC-2 cell |
|
A-010537 |
Purging
tube |
Components of VC-4 cell can be provided separately. In that case,
each sample vial (011835) includes 10 pieces per the sales unit.
VC-5 Voltammetry cell
Voltammetry cells consist of 4 kinds of products - platinum
counter electrode, sample vials, teflon cap and gas purging tube.

Components of VC-5 cell can be provided separately. In this case,
each sample vial (001056) includes 10 pieces per the sales unit.
|
Catalog No. |
Description |
|
A-012188 |
VC-5 Voltammetry
cell |
|
Contents |
|
A-001056 |
Sample vial (20 mL) 7
pcs |
|
A-002233 |
Pt counter electrode for
VC-3 cell 5 cm Pt |
|
A-011885 |
Teflon cap for VC-5 |
|
A-010537 |
Purging tube |
SVC-3 Oxygen-free
Voltammetry cell
By using this cell, researchers can run experiments free from
gasificationed steam. Also, recearchers can get rid of infruelnce of
oxygen in the cell by bubbling nitrogen gas. This features are well
suited for measurements by ultraweak current. Sample volume: 5-10
mL.
 

|
Catalog No. |
Description |
|
A-010914 |
SVC-3
Oxygen-free Voltammetry cell |
|
Contents |
|
A-001056 |
Sample vial (20 ml) 7
pcs |
|
A-002233 |
5 cm Platinum counter
electrode for VC-3 cell |
|
A-011811 |
Teflon cap for SVC-3 |
|
A-010537 |
Purging tube |
Micro volume cell
MCA Micro cell requires only 50-200 µL of analyte. This is an
advantage for the researchers who need to study with a small volume
of sample. Users can select their appropriate working electrodes
from our various CV electrodes.
[How To Use]
- Prepare supporting electrolyte in a cell vial and sample in
the sample holder. Be sure to equalize their electrolyte
concentration.
- Place a counter electrode in the cell vial. When organic
solvent is used, it should be put inside the sample holder to
avoid IR drop at the Vycor glass frit. In that case, please
choose 3 mm diameter of CV electrodes.
- Insert teflon tube into the cell or the sample holder, purge
N2 gas to eliminate oxygen.

[Reminder]
- To lower electric resistance, please soak the Vycor frit of
sample holder into supporting electrolyte solution at least for
one hour prior to use. These frits need to be kept immersed in
solution all of time.
- If obtained data is shifted, IR drop may be caused. In that
case, please increase the supporting electrokyte as much as five
times or add approximately 0.5 M of NaCl.
|
Catalog No. |
Description |
|
A-011520 |
MCA Micro cell kit |
|
Contents |
|
A-001052 |
VC-2 Voltammetry cell |
|
A-012177 |
Sample
holder dia 9 mm (2 pcs) |
Bulk Electrolysis cell

This product is utilized for complete electrolysis. As mentioned
below, carbon working electrode is a reticulated form that provides
with sufficient surface area to gain the rate in electrolysis. The
water jacketed cell can be purchased separately. Platinum mesh
electrode is also available as a custom order. The platinum counter
electrode equips a separating chamber. The progress of an
electrolysis can be investigated by inserting additional indicator
electrode (required to be prepared by users themselves). That
insertion requires a port plug when the indicator electrode is not
used.
Suitable for:
- Quantitation of mass transfer of the electron per molecule
- Measuring the absolute quantity of the analyte
- Electrolytic synthesis of new materials (generally in
quantity of milligram)
- etc.
|
Catalog No. |
Description |
|
A-001197 |
Bulk Electrolysis
Cell |
|
Contents |
|
A-001195 |
100 ml Glass cell |
|
A-010530 |
Porous carbon electrode |
|
A-002234 |
Platinum counter electrode 23
cm |
|
A-001198 |
Lid for counter electrode |
|
A-001196 |
Chamber for counter electrode |
|
A-001236 |
O-ring for counter electrode |
|
A-009131 |
Port plug |
|
A-000178 |
Stirrer bar |
|
A-001199 |
Teflon Cap (for bulk) |
|
A-010537 |
Gas purging tube |
Optional components
|
Catalog No. |
Description |
Size |
|
A-002250 |
Platinum gauze electrode 80
mesh |
25 x 35 mm |
|
A-002251 |
Gold gauze electrode 100 mesh |
25 x 35 mm |
|
A-001194 |
Water Jacketed Glass cell
(for bulk) |
Plate Material
Evaluating cell
 |
This quite handy cell is developed in order
to evaluate plate material such as metal, semi-conducting
plate, etc. In evaluation, a sample plate is sandwiched
between cell blocks.
|
Catalog No. |
Description |
Quantity |
|
A-011951 |
Plate Material Evaluating Cell |
1 |
|
Contents |
|
Teflon Cell [Body] |
1 |
|
Teflon Cell [Base] |
1 |
|
O-ring |
1 |
|
Screw 20 mm |
2 |
|
Purging tube 1 m |
1 |
|
A-002222 |
Pt counter electrode for VC-2 cell |
1 |
|
[Optional Product] Reference Electrode
Users can select a reference electrode separately for this cell
from :
|
Catalog No. |
Description |
|
A-012167 |
RE-1B
Silver-Silver chloride reference electrode |
|
A-012171 |
RE-7 Non
Aqueous reference electrode |
|
A-002058 |
RE-1C
Silver/Silver Chloride Reference Electrode (Saturated
KCl) |
|
A-002056 |
RE-2B
Calomel Reference Electrode |
|
A-002057 |
RE-2C
Reference Electrode |
|
A-011503 |
RE-6H
Reference Electrode Kit available in
alkaline solution |
[ How to Set Up ]
- Place a plate sample on a lower side teflon block of the
cell. Applicable plate dimensions : W: 10-20 mm, T: ~3 mm
- Put another teflon block on the sample, and drive two screws
evenly to fix the plate. Liquid contact area depends on inner
diameter of the O-ring. Deliver approximately 1 ml of
electrolyte after fixing the plate.
- Attach a Pt counter electrode and a reference electrode to
the cell by setting them onto a cell cap. We would recommend you
to twist up the Pt part appropriately if the counter electrode
is longer.

Flow cell
Working Electrodes for Flow Cell
Our Working electrodes for flow cell are mounted on blocks of
PEEK. This resin protects the electrodes from external noise and
allows researchers to utilize them regardless the content of mobile
phase of HPLC because of their hard, organic solvent-resistance.
Glassy carbon is usually chosen for the redox reaction study on
liquid chromatography. Platinum, Gold, Carbon paste and Nickel
electrodes are utilized for special purposes.Features
- Become stable immediately
- Usable with acid, alkaline, and organic solvents
- Easy maintenance of Working electrodes by wipe with acetone
- Working electrodes can be refreshed using PK-3 cell
Polishing Kit
- Can be used as chemically modified electrodes or bio-sensors
Cross Flow Cell - Structure
Cross Flow Cell is capable of quantitation at the level of 10-15
mol by the flow rate: 1 mL/min - 100 µL/min.

Features
- Detection electrode for HPLC
- Electrode for flow injection
- Electrode for bio-sensor development
|
Catalog No. |
Description |
Application |
|
A-002456 |
Cross flow cell (Glassy
Carbon) |
Working electrode: GC,
dia. 3 mm x 2 (dual type) |
|
A-002457 |
Cross flow cell (Platinum) |
Working electrode: Pt,
dia. 3 mm x 2 (dual type) |
|
A-012122 |
Cross flow cell (Gold) |
Working electrode: Au,
dia. 3 mm x 2 (dual type) |
|
Contents |
|
Item |
Material |
Quantity |
| Working
Electrode for cross flow cell |
|
1 |
|
Reference Electrode (RE-3V Silver-silver
chloride Reference electrode Screw type) |
POM *1 |
1 |
| Cross
Flow cell block |
PEEK *2 |
1 |
| Flow
cell base block |
POM |
1 |
| Screw
for base block |
SUS *3 |
2 |
| Flow
cell arm |
SUS |
2 |
| Screw
for arm |
SUS |
2 |
| Working
Electrode connector |
brass |
1 |
| Hand
screw for clamp |
SUS |
1 |
|
Stainless plate for clamp |
SUS |
1 |
| Clamped
plate |
SUS |
1 |
| Teflon
tube |
ETFE |
30 cm
80 cm |
| Silicon
tube |
Si |
2 cm
28 cm |
|
Stainless pipe 5 cm |
SUS |
1 |
| TG-5M
Teflon Gasket (Cross Flow) |
FEP |
1 |
| Dynaseal
PEEK fingertight |
PEEK |
3 |
*1 Polyacetal resin *2 Polyether-ether-ketone *3 Stainless Used
Steel
Cross Flow Cell - Working Electrode

Radial Flow cell
Radial Flow Cell is developed for microbore chromatography. Its
detecting efficiency will improve when flow rate is 10 µL/min or
lower. This flow cell consists of thin layer electrode and symmetric
design.

|
Catalog No. |
Description |
Application |
|
A-003456 |
Radial flow cell (Glassy
Carbon) |
Working electrode: GC,
dia. 6 mm (single type) |
|
A-003457 |
Radial flow cell (Platinum) |
Working electrode: Pt,
dia. 3 mm (single type) |
|
A-011236 |
Radial flow cell (Gold) |
Working electrode: Au,
dia. 3 mm (single type) |
|
Contents |
|
Item |
Material |
Quantity |
| Working Electrode for
Radial flow cell |
|
1 |
| Reference Electrode
(RE-3V Silver-silver chloride Reference electrode Screw
type) |
POM |
1 |
| Radial Flow cell block |
PEEK |
1 |
| Flow cell base block |
POM |
1 |
| Screw for base block |
SUS |
2 |
| Flow cell arm |
SUS |
2 |
| Screw for arm |
SUS |
2 |
| Hand screw for clamp |
SUS |
1 |
| Stainless plate for
clamp |
SUS |
1 |
| Clamped plate |
SUS |
1 |
| Teflon tube |
ETFE |
30 cm
80 cm |
| Silicon tube |
Si |
2 cm
28 cm |
| Stainless pipe 5 cm |
SUS |
1 |
| TG-5MR Teflon Gasket
(Radial Flow) |
FEP |
1 |
| Dynaseal PEEK
fingertight |
PEEK |
3 |
Electrodes and Accessories for Flow Cell Kit
Application of Electrodes
- GC: commonly used for measurement of Redox behavior
- PFC: commonly used for measurement of Redox behavior
- Au: measurement of thiol-related compounds with amalgamate
electrode
- Pt: measurement of hydrogen peroxide and oxidized substance
- Ag: measurement of cyano-sulfide
- CP: derivatizationed electrode by filling compound of carbon
paste, enzyme and chemical substance into it
- Ni: amino acids measurement by chemical derivatization
|
Type |
Catalog No. |
Item |
Description |
Cross
Flow |
A-001000 |
Glassy Carbon Electrode
for cross flow cell |
dia. 3 mm x
2 (dual type),
Size: 25 x 25 mm |
|
A-001002 |
Gold Electrode for cross
flow cell |
|
A-001012 |
Platinum Electrode for
cross flow cell |
|
A-001008 |
Silver Electrode for
cross flow cell |
|
A-001004 |
Carbon Paste Electrode
for cross flow cell |
|
A-001009 |
Nickel Electrode for
cross flow cell |
|
A-001046 |
TG-2M Teflon Gasket (4
pcs) |
Film thickness: 12 µm |
|
A-001047 |
TG-5M Teflon Gasket (4
pcs) |
Film thickness: 25 µm |
|
A-001048 |
TG-6M Teflon Gasket (4
pcs) |
Film thickness: 50 µm |
|
A-001049 |
TG-8M Teflon Gasket (4
pcs) |
Film thickness: 125 µm |
|
A-001092 |
TG-11M Silicon Gasket (4
pcs) |
Film thickness: 500 µm |
|
A-001093 |
TG-12M Silicon Gasket (4
pcs) |
Film thickness: 1000 µm |
|
A-001032 |
Cross Flow cell block |
Material: PEEK |
Radial
Flow |
A-001016 |
Glassy Carbon electrode
for Radial flow cell |
dia. 6 mm
(single type),
Size: 25 x 25 mm |
|
A-010941 |
Copper electrode for
radial flow cell |
|
A-009908 |
Platinum electrode for
radial flow cell |
dia. 3 mm
(single type),
Size: 25 x 25 mm |
|
A-011155 |
Gold Electrode for
radial flow cell |
|
A-000999 |
PFCE Carbon electrode
for radial flow cell |
|
A-010251 |
Carbon Paste Electrode
for radial flow cell |
|
A-001146 |
TG-2MR Teflon Gasket (4
pcs) |
Film thickness: 12 µm |
|
A-001147 |
TG-5MR Teflon Gasket (4
pcs) |
Film thickness: 25 µm |
|
A-001148 |
TG-6MR Teflon Gasket (4
pcs) |
Film thickness: 50 µm |
|
A-001031 |
Radial Flow cell block |
Material: PEEK |
|
Cross/Radial |
A-012169 |
RE-3V Ag/AgCl Reference
electrode screw type |
Size: dia. 10 x 48 mm |
|
A-001531 |
1/16" PEEK tube |
ID: 0.25 mm, Length: 3.0
m |
|
A-004130 |
Dynaseal PEEK
fingertight (10 pcs) |
Screw for pipe
connecting
integrated 1/16" |
Spectroelectrochemical
cell
Spectroelectrochemistry (SEC) is aimed at the investigation of
electrochemical reaction mechanism and the interface structure
between electrolyte solution and electrode. Remarkable progress in
this field and related technology enables SEC to be applied in wide
areas. Nowadays, the relation between absorbance and potential for
reversible or quasi-reversible system is theoretically elucidated,
on which basis the analysis of electrochemical characteristics
becomes possible for the system otherwise difficult with only the
result of voltammogram. Typical example is redox enzyme cytochrome c
and methylene-blue

- Real-time monitoring of chromatic change by red-ox reaction
- Analysis of the charge transfer at the electrode/liquid
surface
- Spectrometric measurement of near/surface of electrodes
- Absorbing spectrum of the product and intermediate
- Parameters; concentration, diffusion coefficient and life
time

|
Catalog No. |
Description |
|
A-011240 |
SEC-C Thin Layer Quartz Glass
Spectroelectrochemical cell Kit |
|
Components |
|
A-011498 |
SEC-C Pt
Gauze working electrode |
|
A-011499 |
SEC-C Pt
counter electrode |
|
A-011500 |
SEC-C Thin Layer Quartz
Glass cell |
Light pass length: 1 mm |
|
A-011501 |
SEC-C Teflon
Cap |
|
A-010537 |
Purging tube |
 

Front view |

Side view |

Reference Electrode for SEC-C
Reference Electrode can be chosen optionally from below:
|
Catalog No. |
Description |
|
A-012167 |
RE-1B Silver-Silver
chloride reference electrode |
Length:
80.0 mm |
OD: 6.0 mm |
|
A-012171 |
RE-7 Non Aqueous
reference electrode (Ag/Ag+) |
Length:
80.0 mm |
OD: 6.0 mm |
Working Electrode for SEC-C

|
Catalog No. |
Description |
|
A-012017 |
SEC-C Au Gauze working
electrode |
|
A-011498 |
SEC-C Pt Gauze working
electrode |
Spectroelectrochemical flow cell
Applications:
- Study of charge transfer mechanism on the interface between
electrode and electrolyte.
- Spectroscopy on electrode surface or in the neighborhood.
- Absorption spectra of products and intermediates.
- Analysis of concentration, diffusion coefficient, life time
so on.
Schematic view of flow cell (thin layer flow channel, light pass
and working electrode) is shown below. Working electrodes (ITO,
platinum mini-grid, and gold mini-grid) are replaceable. UV or
visible light is introduced via optical-fiber from light source and
the absorbed light is transferred into CCD via optical-fiber.
Example of spectrum change during oxidation-reduction of ferrocene
by CV is shown below.
Spectroelectrochemical electrodes

Schematic diagram of spectroelectrochemical flow cell


Pt and Gold mini Grid electrode

Pt mini-grid electrode is made by sputtering on quartz plate as
shown in below picture. Size is 8 × 27mm, width of grid line is
150μm, space between lines is 100µm.

|
Cat No. |
Description |
|
A-011320 |
SEC-F
Spectroelectrochemical flow cell |
|
Contents |
|
A-011329 |
SEC-F
flow cell base |
|
A-011330 |
SEC-F
flow cell block (A) |
|
A-011331 |
SEC-F
flow cell block (B) |
|
A-011495 |
SEC-FT500 Teflon gasket (2 pcs) |
|
A-010562 |
74-UV
UV/VIS Collimating Lens, 200-2000 nm |
|
------ |
Dynaseal
PEEK fingertight (3 pcs) |
|
------ |
Teflon
tube (80 cm) |
|
------ |
Silicon
tube (30 cm) |
|
------ |
Stainless tube OD 1/16" (50 mm) |
Optional Products
|
Cat No. |
Description |
|
A-011810 |
SEC-F 1000 µm probe type
of optical fiber |
Length: 1 m |
|
A-011496 |
SEC-F Pt grid electrode
for flow cell |
8 x 27 x 1 mmt |
|
A-011497 |
SEC-F Au grid electrode
for flow cell |
8 x 27 x 1 mmt |
|
A-011519 |
SEC-F ITO electrode for
flow cell (4 pcs) |
8 x 27 x 1 mmt |
|
A-012169 |
RE-3V Silver-silver
chloride Reference electrode Screw type |
φ10 x 55 mm |
|
A-012173 |
RE-7V Non Aqueous
reference electrode (Ag/Ag+) Screw type |
φ10 x 55 mm |
Sample holders
These products enable to take electrochemical measurement by only
200 µL of the analyte with voltammetry cells. A vycor glass tip is
attached to the end of its glass tube, and ions transmit freely.

|
Catalog No. |
Description |
SIZE |
|
A-012177 |
Sample holder dia 9.0 mm
(2 pcs) |
OD6 mm, ID7 mm, L55 mm |
|
A-012176 |
Sample holder dia 6.0 mm
(2 pcs) |
OD9 mm, ID4 mm, L55 mm |
|
A-012175 |
Sample holder dia 4.5 mm
(2 pcs) |
OD4.5 mm, ID2 mm, L40 mm |
Vycor Glass products
Vycor® glass is porous glass with 40-200 Å diameter of pores.
Chemically stable, operational as high as 800 °C. Also can be cut
with a sharp knife.
Reminder:
Yellowish discoloration indicates the contamination. This is caused
by absorbing of organics into their pores from the air.
Specifications
|
Specific gravity [in dry condition] |
1.5 |
|
Void volume |
28 % |
|
Avr. pore diameter |
40-200 Å |
|
Internal surface area |
250 m2/g |

|
Catalog No. |
Description |
Quantity |
|
A-012182 |
Vycor
Glass Rod, dia 2.85x4.0 mm |
25 pcs |
|
A-012183 |
Heat
shrink Teflon tubing, 100 mm |
1 |
|
A-001087 |
Vycor
glass tube
(OD:7 mm; ID:5 mm; Length:10 cm) |
1 |
PK-3 Electrode
Polishing kit
Polishing kit to maintain good condition of working electrodes
for CV/Flow cell.
|
Catalogue No. |
Description |
|
A-011975 |
PK-3 Electrode Polishing kit |
|
Contents |
|
A-001050 |
0.05 µm
polishing alumina (20 ml) |
|
A-002054 |
1 µm
polishing diamond (10 ml) |
|
A-001040 |
Alumina
polishing pad (10 pcs) |
|
A-001041 |
Diamond
polishing pad (10 pcs) |
|
A-002249 |
Replacement glass plate for PK-3 (1 pc) |
Contents of PK-3 can be provided separately. In that case, each
polishing pad (A-001040 Alumina polishing pad/A-001041 Diamond
polishing pad) includes 20 pieces of them per the sales unit.
How to polish the Working electrodes' surface with PK-3

- Prepare the glass plate, and put a few drops of polishing
diamond on diamond polishing pad.
- Hold the CV electrode at right angle to the pad, and polish
in a circular motion.
- Replace the diamond pad to an alumina polishing pad, put a
few drops of polishing alumina, and polish the electrode to be
mirror surface. Rinse the electrode surface with distilled water,
and finish by air drying.
Attention: Polishing with PK-3 is the most appropriate way to
clean up electrode surface. Please consult us when other methods
are applied.
Polishing of PFCE Electrode & Pyrolytic Graphite Electrode
PFCE electrode can regain its electrochemical sensitivity and
reproducibility by polishing with Emery paper sic#4000. After the
polishing, please clean its surface with ultrasonic cleaner for
10-60 seconds (@ frequency: 50 KHz, output power: 100 W). PFCE
electrode is a significantly competent electrode. In order to keep
its performance from going to be eroded, we recommend re-polishing
after a certain period of time.
Use of distilled water is required during this procedure.
Sic#2000 grade emery paper is used at the preliminary stage only for
persistent stain.
Notice*
Don't polish with a finer grade of emery paper ( #6000 etc.).
PFCE electrode do not need mirror finish surface like a GC
electrode.
|