What is new in EC-Lab® V9.5


NEW FEATURES

  • New techniques

Special Applications techniques = SOCV, SMP, SMG, SGCPL. Conditional limits on Analog Input 1 or 2 are defined in these techniques, derived from already available techniques.

  • New graph properties windows

All the graph properties can be defined with this window such as traces to display, axes or units. The Traces menu is a way to select the graph to display but also the graph style (lines, markers). In the Axes menu, the user can define the title of the graph, the scale or choose to invert axis, but also choose if he wants a XY proportional representation. The Units menu allows the user to select the unit of the displayed variables. In the Graph menu, selection of the legend, title and graph background can be done. The definition of the current convention or of the monitor size (for good adaptation to the graph size) can be done in the Options menu. Once all the graph properties defined, it is possible to name the graph style and to save it, then one Graph Style is defined. Thus, this Graph Style can be used for all recorded data.

  • New Graph Representation selection

A new window dedicated to the Graph Representations has been created. This new menu allows the user to select for each technique a representation:

  • the variable to display on each axis,
  • the process function with a mathematical function for each axis,
  • the name of the representation,

This new window is a good way to customize and automate a graphic representation.

  • EIS techniques: Multisine measurement

It is now possible to choose between single or multi sine measurement for every EIS technique. Multisine measurement is defined for two decades of twenty frequencies and for frequencies smaller than 1 Hz. Generally multisine measurement is three time faster than single sine one.

  • Detection of new instruments: CLB-500 and LB-500

IMPROVEMENTS

  • New techniques: Manual IR (MIR) and IR compensation (ZIR).
    • Manual IR: the value to compensate is defined by the user,
    • IR compensation (PEIS): automatic ohmic drop determination done by an Electrochemical Impedance Spectroscopy measurement and compensation for the rest of the experiment.
  • New cursor button in the Graph menu allowing the user when left-clicking on the mouse to display data point coordinates with x, y and the number of the recorded points.
  • Zoom +/- with mouse wheel.
  • New mathematical functions integrated in the Trace processing tool to be applied on each axes.

  • Removing of comments with Del. key.
  • Possibility for the user to define the Axes name and the Title of the graph.
  • Integration of the USB Vista driver.
  • Mott-Schottky plot: add of the 1/C plot.
  • Number of connected PC at the same instrument = 16.
  • New export format: EPS.
  • Save button on the Channel calibration menu.
  • Modification of the Reset Channel menu for complete reset of the channel which was not the case actually.
  • Modification of the Repair Channel menu.

ERROR CORRECTIONS

  • In some cases, modification on the fly of EIS techniques parameters was not properly done.
  • In the Wait technique, the date was not working properly.
  • The calculation of the number of cycle was not working properly for the VMP1 instrument.
  • In Tafel analysis, current density calculation was not working properly.
  • In some case, EIS measurements with LC board was not working properly and can reach the 1 A current range.
  • In some cases, the experiment parameters were not properly loaded when working with grouped channels.

EC-Lab® - download

EC-Lab® is available for free download to registered users. Click here to access the support section

For a List of web's modification

Click here

 