Software upgrade & help


JTS-10 Software V1.21 (Online November 24, 2011)

  • Click here to download the software
  • Software detailed history

JTS-10 software/hardware compatibility

The JTS-10 software was modified to work with the new PCIe-6535 from National Instruments. A standard PCI express slot is needed to install the plug-and-play board. The previous board PCI 6533 is still supported by version 1.21 and higher.
Note: the NIDAQmx drivers V9.1.1 or higher is needed for the JTS-10 software V1.20 or higher.

JTS-10 Manual V1.21 (Online November 24, 2011)

Software installation

  • Create an empty directory, unzip the downloaded file in this directory and run <setup.exe> from the JTS-10 sub-directory. Do not install this new version over a previous one : rename the directory or use a different one.
  • After connecting the JTS-10 control unit to the USB port of the computer, you will be asked for a driver. Select the driver_usb_2000_xp directory from the installation package.
  • Also please look at technical note #0: JTS-10 hardware and software installation.

Note : This version requires Windows2000, WindowsXP, Win7-32 or Win7-64 and the NI-DAQ drivers supplied with the PCI-6535 from NI. See the following link to download the drivers.

 

 

Application notes
( November 8, 2011 )

  • AN#1 - The advantages of using green light to follow fluorescence changes.
  • AN#2 - Cyclic and linear eletron flow in plants revealed by JTS-10 spectrometer.
  • AN#3 - Cyclic electron flow in C3 plants.

Technical notes
(accessible to registered users only - List updated on November 8, 2011)

  • TN#0 - Hardware and software installation (updated November 8, 2011)
  • TN#1 - Use of Eukaryote Kit in Absorbance mode - ECS measurement with PSI excitation.
  • TN#2 - Use of Eukaryote Kit in Absorbance mode - ECS measurement with PSI and PSII excitation.
  • TN#3 - Use of Eukaryote Kit in Fluoresccence mode - OJIP measurement using Fluo-59 accessory.
  • TN#4 - Use of Eukaryote Kit in Fluorescence mode - NPQ measurement using Fluo-59 accessory.
  • TN#5 - Use of Cytochrome Eukaryote Kit in Absorbance mode - Cytochrome b and f measurement with PSI excitation.
  • TN#6 - Use of P700-705 Kit in Absorbance mode - P700 and PC measurements with PSI and PSII excitation.
  • TN#7 - Use of P700-705 Kit in Absorbance mode - P700 and PC measurements with PSI excitation.
  • TN#8 - Interfacing a laser to JTS-10

Important Notes

  • The links marked with a requires a login and password which will be emailed (by a human) to you once you register your instrument.
  • You can use the following link to register your instrument or ask for help.
  • Please use the following link to fill our online survey. It is very important for us to know where we need to improve.
  • The username & password have changed October 1st 2007, you may need to register again.

 

 

Contact us - Legal notice - Chinese reg.num.(京ICP备06015605号) - Last modified: 4-feb-11 - ©2004-11 Bio-Logic SAS - American Express CB Master Card Visa PayPal